Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 1 de 1
Filter
Add filters








Year range
1.
J. vasc. bras ; 20: e20210098, 2021. tab, graf
Article in Portuguese | LILACS | ID: biblio-1356453

ABSTRACT

Resumo Contexto A insuficiência renal crônica é um problema de saúde pública mundial. A hemodiálise é a principal terapia renal substitutiva. As fístulas arteriovenosas (FAV) são uma possível escolha, mas apresentam altas taxas de falência. Objetivos Este estudo tem como objetivo avaliar a relação entre as variáveis hemodinâmicas ao ultrassom vascular com Doppler no intraoperatório e a perviedade precoce da FAV para hemodiálise. Métodos Tratou-se de um estudo prospectivo observacional. Os pacientes consecutivos foram submetidos a FAV com ultrassonografia vascular com Doppler em intraoperatório nos dias 1, 7, 30 e 60. Eles foram divididos em grupos quanto à presença ou não de perviedade primária e secundária, e o volume de fluxo (VF) e a velocidade de pico sistólico (VPS) foram comparados. Foram realizadas curvas receiver operating characteristic (ROC), com definição de valores de VPS e VF com sensibilidade (S) e especificidade (E). Resultados Foram analisados 47 pacientes, os quais preencheram os critérios de inclusão. Os valores de VPS e VF intraoperatório foram maiores nos pacientes com perviedade primária e secundária comparados àqueles com falência. Os seguintes valores apresentaram maiores sensibilidade e especificidade para predizer perviedade primária aos 30 dias: 106 cm/s para VPS venoso, S: 75%, E: 71,4%; e 290,5 mL/min para VF arterial, S: 80,6%, E: 85,7%. Para perviedade secundária aos 30 dias, foram observados: 106 cm/s para VPS arterial, S: 72,7%, E: 100%; e 230 mL/min para VF venoso, com S: 86,4%, E: 100%. Para a perviedade primária no 60º dia, foram observados: 106 cm/s para VPS venoso, S: 74,4%, E: 62,5%; e 290,5 mL/min para VF arterial, S: 80%, E: 75%. Conclusões A velocidade de pico sistólico e o VF ao ultrassom vascular com Doppler intraoperatório são preditores de perviedade precoce na FAV para hemodiálise.


Abstract Background Chronic kidney disease is a major public health problem. Hemodialysis is the most common renal replacement therapy. Arteriovenous fistulas (AVF) are a possible access option, but early failure rates remain high. Objectives to investigate the value of intraoperative vascular Doppler ultrasound for predicting early AVF patency. Methods Prospective observational study. Consecutive patients undergoing AVF were assessed with vascular Doppler ultrasonography intraoperatively and on days 1, 7, 30, and 60. Patients were divided into groups according to presence or absence of primary and secondary patency. Blood flow (BF) and peak systolic velocity (PSV) were compared. ROC curves were plotted and used to define the PSV and BF values that yielded greatest sensitivity (Sens) and specificity (Spec). Results 47 patients met the inclusion criteria and were analyzed. Higher intraoperative PSV and BF values were observed in patients who had primary and secondary patency than in patients with access failure. The values with greatest sensitivity and specificity for predicting 30-day primary patency were 106 cm/s for venous PSV (Sens: 75% and Spec: 71.4%) and 290.5 ml/min for arterial blood flow (Sens: 80.6% and Spec 85.7%). Values for 30-day secondary patency were 106 cm/s for arterial PSV (Sens: 72.7%, Spec: 100%) and 230 ml/min for venous blood flow (Sens: 86.4%, Spec100%). Values for 60-day primary patency were 106 cm/s for venous PSV (Sens: 74.4%, Spec: 62.5%) and 290.5 ml/min for arterial blood flow (Sens: 80%, Spec: 75%). Conclusions Peak systolic velocity and blood flow measured using intraoperative vascular Doppler ultrasound can predict early patency of hemodialysis arteriovenous fistulas.


Subject(s)
Humans , Male , Female , Adult , Middle Aged , Aged , Vascular Patency , Arteriovenous Fistula/diagnostic imaging , Ultrasonography, Doppler/methods , Arteriovenous Shunt, Surgical/adverse effects , Prospective Studies , Renal Dialysis , Hemodynamic Monitoring/methods , Intraoperative Care/methods
SELECTION OF CITATIONS
SEARCH DETAIL